日韩在线一区二区-一区二区久久-中文字幕综合-91日韩在线-99国产精品99久久久久久粉嫩-四虎在线免费视频-日韩美女一级片-二区在线视频-国产亚洲色婷婷久久99精品-一曲二曲三曲在线观看中文字幕动漫-亚洲视频在线观看一区-亚洲黄色三级视频-久久精品香蕉-亚洲人成色777777精品音频-91大片在线观看-视频二区中文字幕-天天夜夜骑-极品少妇在线-一级激情视频-岛国精品视频-牛牛热在线视频-亚洲熟妇av一区二区三区-蜜桃视频在线观看一区-一本色道久久88综合日韩精品-国产欧美久久久精品免费-深爱激情久久-欧美二区三区视频-你懂的在线国产-黄色第一网站-国产精品自拍视频一区

Welcome to Ningbo Chaori Hydraulic.Co.Ltd.!
CN EN ES
Hotline

(86)13208083169

0574-88850227

Principle of Accumulator

1. The working principle of the accumulator

The accumulator is a hydraulic accessory designed to accumulate pressurized liquid. The liquid is incompressible. The accumulator uses the compressibility of the gas to achieve the purpose of storing the liquid. When the pressure rises, the oil enters the energy storage. The gas is compressed by this, and when the pressure drops, the compressed gas expands and the oil is hydraulically fed into the circuit.

蓄能器工作原理圖片一

  

2. Capacity selection of accumulator

Definition of state parameters

P0=pre-charge pressure V0=effective gas volume

P1=minimum working pressure V1=gas volume at P1

P2=maximum working pressure V2=gas volume at P2

tmin=minimum working temperature t0=pre-charge gas temperature

tmax=maximum working temperature n=variable index

① The state before use (nitrogen and liquid have not entered).

② The capsule is pre-filled with nitrogen gas, and the oil valve is closed to prevent the capsule from detaching.

③ When the minimum working pressure is reached, a small amount of oil should be kept between the outside of the capsule and the oil valve (about 10% of the nominal capacity of the accumulator), so that the capsule will not hit the valve during each expansion process and cause damage to the capsule.

④ The accumulator is at the highest working pressure. The volume change at the minimum and maximum working pressures corresponds to the effective fluid volume. △V=V1—V2


3. Selection of pre-charge pressure

The bladder accumulator NXQ series allows volume utilization of 75% of the actual gas capacity. Therefore, the ratio between the pre-charge nitrogen pressure and the maximum working pressure is limited to 1:4, and the pre-charge pressure should not exceed 90% of the minimum system pressure. Following this rule guarantees a long capsule life. Other compression ratios can be achieved with special measures.

In order to fully utilize the capacity of the accumulator, it is recommended to use the following values.

Energy storage: P0tmax=0.9×P1 Shock absorption: P0tmax=(0.6~0.9)×Pm(Pm=average working pressure of free circulation)

Absorption pulsation: P0tmax=0.6×Pm (Pm=average working pressure) or P0tmax=0.8×P1 (at various working pressures)

The limit value of pre-charge pressure: P0≤0.9×P1, the allowable compression ratio is P2:P0≤4:1


4. Calculation formula for accumulator capacity selection

The compression and expansion process in the accumulator should follow the law of changing gas states.

The ideal gas is: P0×Vn 0=P1×Vn 1=P2×Vn 2

Among them, the influence index of the variable index "n" on the gas characteristics over time should be considered.

The state change of the slow expansion and compression process is close to isothermal, and the variable index can be n=1

And the rapid expansion and compression process occurs adiabatic state change, the multivariable index n=1.4 (suitable for diatomic gas nitrogen)

TIM截圖20180529142030.png